Uniform Polymer Microspheres™
for Diagnostic Assays
PolyMicrospheres takes pride in providing the highest quality microspheres for our customers in clinical diagnostics. Since its founding in 1990, PolyMicrospheres has become the recognized leader in microparticle development and innovation.
With decades of research experience in polymer science, process engineering, and microparticle technology, PolyMicrospheres is the pioneer in the creation of uniform polymer microspheres specifically designed for diagnostic assays. Using state-of-the-art facilities and the most innovative polymerization techniques, we develop and manufacture a complete line of uniform microspheres with a variety of particle sizes and surface chemistries. In addition, we offer semi-custom and custom microspheres, optimized and fine-tuned with the proper surface morphology and the correct level of functionality to suit your application.
Our emphasis has been on the innovation of new products through dedicated research. The precision and accuracy of our techniques, together with computerized formulations, GMP and ISO9001 certified manufacturing practices, provide the highest quality and constantly reproducible microspheres with the best distribution of size, functionality, and morphology. We are equipped with numerous custom-designed glass/glass-lined reactors and process controllers to produce up to 400 liters of microspheres in a single production run.
We are specialized in developing cutting-edge technologies for the new millennium. We are devoted to fostering the development of new diagnostic assays and kits.
We look forward to providing your organization with a truly competitive edge.
Buy from PolyMicrospheres, where the microparticles are designed, developed and manufactured.
Products
Choices for covalent coupling to Carboxyl microspheres:
- Carboxyl microspheres
More than 100 products The right particle size with correct level of COOH groups (40 to 400 µEq/g of carboxyl groups) for best coupling efficiency
- SpaceLink™ microspheres
Flexible spacer arms (~10A°) and linker groups already attached for the covalent coupling of ligands, especially for bulky ligands Improved kinetics of agglutination reactions
Choices for simple one-step covalent coupling to microspheres (preactivated):
Choices for binding to Plain-Surface microspheres:
- Polystyrene microspheres
More than fifty products Optimized levels of sulfate groups for stabilization and best passive adsorption
Other microspheres:
- Precleaned microspheres: available in all of the above products on order
- Solvent-resistant microspheres
- Custom and semi-custom microspheres to your exact specs
- Particle size and calibration standards
- Specialty microspheres for imaging, FPD, and LCD applications
We fine-tune diagnostic microspheres for the right size and surface chemistry and the correct level of functionality to suit your specific application. We welcome the opportunity to be a part of your diagnostic development and manufacturing program.
Carboxyl Products
Carboxyl Microspheres
Our high degree of specialization and expertise in microparticle technology enabled us to concentrate on all aspects of carboxyl microspheres. An enormous amount of research work has been focused on the development of every possible carboxyl microsphere for diagnostic assays. Within each size, we offer different levels of functionality to provide a range of selectivity, sensitivity, and specificity as desired for each application.
- More than 100 products - various sizes and surface charge densities
- Optimized levels of carboxyl and sulfate groups for maximum coupling efficiency
- Very uniform surface morphology and even distribution of functional groups
- Can be used without precleaning for most applications
- Highly uniform, stable, and reproducible
- Fluorescent and Dyed microspheres: Available in selected sizes
Diameter, nm |
Catalog Number |
Carboxyl µEquiv/gram |
Parking Area |
20 |
CB0020I |
250 |
173.0 |
25 |
CB0025G |
230 |
165.0 |
30 |
CB0030F |
190 |
166.4 |
35 |
CB0035G |
230 |
117.8 |
42 |
CB0042G |
200 |
112.9 |
46 |
CB0046I |
260 |
79.3 |
50 |
CB0050I |
260 |
73.0 |
52 |
CB0052G |
230 |
79.3 |
62 |
CB0062F |
200 |
76.5 |
71 |
CB0071D |
120 |
111.3 |
72 |
CB0072F |
180 |
73.2 |
81 |
CB0081D |
140 |
83.6 |
94 |
CB0094D |
130 |
77.6 |
97 |
CB0097C |
100 |
97.8 |
98 |
CB0098D |
115 |
84.2 |
100 |
CB0100E |
170 |
55.8 |
104 |
CB0104D |
110 |
82.9 |
105 |
CB0105D |
110 |
82.1 |
115 |
CB0115D |
110 |
75.0 |
120 |
CB0120F |
190 |
41.6 |
122 |
CB0122C |
80 |
97.2 |
127 |
CB0127D |
120 |
62.2 |
130 |
CB0130E |
170 |
42.9 |
135 |
CB0135F |
200 |
35.1 |
136 |
CB0136C |
90 |
77.5 |
136 |
CB0136E |
170 |
41.0 |
140 |
CB0140E |
170 |
39.9 |
146 |
CB0146D |
105 |
61.9 |
160 |
CB0160B |
65 |
91.2 |
172 |
CB0172E |
160 |
34.5 |
193 |
CB0193F |
190 |
25.9 |
195 |
CB0195B |
65 |
74.8 |
201 |
CB0201E |
165 |
28.6 |
206 |
CB0206D |
120 |
38.4 |
207 |
CB0207E |
170 |
27.0 |
210 |
CB0210C |
85 |
53.1 |
213 |
CB0213E |
116 |
27.8 |
226 |
CB0226C |
85 |
49.4 |
230 |
CB0230D |
125 |
33.0 |
258 |
CB0258D |
110 |
33.4 |
267 |
CB0267D |
105 |
33.8 |
286 |
CB0286C |
90 |
36.9 |
297 |
CB0297C |
100 |
31.9 |
300 |
CB0300B |
70 |
45.2 |
309 |
CB0309B |
70 |
43.9 |
313 |
CB0313C |
100 |
30.3 |
350 |
CB0350B |
70 |
38.7 |
358 |
CB0358B |
60 |
44.2 |
376 |
CB0376C |
80 |
31.5 |
385 |
CB0385B |
65 |
37.9 |
394 |
CB0394B |
70 |
34.4 |
408 |
CB0408B |
60 |
38.7 |
419 |
CB0419D |
110 |
20.6 |
420 |
CB0420C |
80 |
28.2 |
600 |
CB0600D |
105 |
15.1 |
614 |
CB0614B |
70 |
22.1 |
840 |
CB0840B |
70 |
16.1 |
930 |
CB0930D |
100 |
10.2 |
1020 |
CB1020B |
70 |
13.3 |
1120 |
CB1120C4 |
60 |
14.1 |
1730 |
CB1730C4 |
25 |
21.9 |
We also make it to your exact specs. |
Near-Soap-Free™ Carboxyl Microspheres
PolyMicrospheres innovative process technology has led to the development of a novel product line, “Near-Soap-Free” carboxyl microspheres with high MW. The surface chemistry is similar to conventional microspheres, very uniform and stable, but with very little surfactants.
- Better than soap-free microparticles with no residual monomer and with optimum amount of sulfate groups
- The very little surfactant level with a novel process technology provides stability and uniformity throughout the polymerization
- Surfactant levels of the products are very low (from 0.01% to 0.05%) and do not require clean up
- Optimized levels of carboxyl groups and uniform surface morphology for maximum coupling efficiency
- Highly uniform, stable, and reproducible
- Fluorescent and Dyed microspheres: Available in selected sizes
- We also make it to your exact specs
Diameter, nm |
Catalog Number |
Carboxyl µEquiv/gram |
Parking Area |
120 |
NS0120F |
200 |
39.5 |
135 |
NS0135G |
220 |
31.9 |
195 |
NS0195F |
200 |
24.3 |
207 |
NS0207F |
185 |
24.8 |
300 |
NS0300D |
110 |
28.7 |
315 |
NS0315C |
100 |
30.1 |
380 |
NS0380C |
80 |
31.2 |
420 |
NS0420C |
80 |
28.2 |
600 |
NS0600D |
110 |
14.4 |
SpaceLink™ Carboxyl Microspheres
SpaceLink™ Carboxyl Microspheres are perfect immunodiagnostic reagent particles with a spacer-linker already attached to the microspheres. The length of the flexible spacer arm is ~10A°. The end of the spacer arm has a carboxyl group for covalent attachment of ligands. The second generation of SpaceLink microspheres have been developed and tested at ß-sites for best coupling efficiency.
The benefits of SpaceLink™ Carboxyl microspheres include:
- Almost all of the ligands coupled to the microspheres will be in an active form
- Conformational changes or orientation problems of the ligands are minimized when the ligands are located away from the surface of the particles
- Higher level of sensitivity compared to direct surface coupling; Lesser amount of ligand needed to get the required sensitivity
- The flexible spacer arms improve the kinetics of agglutination reactions and reactivity of each coupled ligand by keeping the ligands away from the surface of the particles
- Antigen/antibody recognition sites line up much more easily
- The flexible spacer arms greatly reduce steric hindrance problems
- We also make it to your exact specs
- Also available: SpaceLink Hydroxyl microspheres
Diameter, nm |
Catalog Number |
Carboxyl µEquiv/gram |
Parking Area |
95 |
SL0095C |
60 |
166.4 |
107 |
SL0107C |
90 |
98.5 |
175 |
SL0175C |
60 |
90.3 |
200 |
SL0200C |
55 |
86.2 |
240 |
SL0240C |
55 |
71.9 |
280 |
SL0280C |
45 |
75.3 |
300 |
SL0300C |
45 |
70.3 |
382 |
SL0382C |
40 |
62.1 |
591 |
SL0591C |
40 |
40.1 |
1010 |
SL1010C |
35 |
26.8 |
Specialty Carboxyl with steric effects
These microspheres are designed with bulky groups to minimize passive adsorption and reduce non-specific binding.
Diameter, nm |
Catalog Number |
Carboxyl µEquiv/gram |
Parking Area |
165 |
SE0165E3X |
160 |
35.9 |
296 |
SE0296C2X |
90 |
35.6 |
310 |
SE0310C6X |
82 |
37.3 |
Hydrophilic Carboxyl Microspheres
These microspheres are designed to enhance stability and reactivity.
Diameter, nm |
Catalog Number |
Carboxyl µEquiv/gram |
Parking Area |
100 |
HC0100G |
230 |
41.2 |
182 |
HC0182E |
145 |
35.9 |
200 |
HC0200E |
170 |
27.9 |
300 |
HC0300C |
90 |
35.1 |
Omni-Bind™ Lipophilic Carboxyl Microspheres
Our innovative process technology and formulations have led to the development of novel lipophilic (lipid incorporated/coated) carboxyl microspheres. These microspheres have been developed with optimized levels of different lipids to increase the coupling efficiency of various proteins.
- The lipophilic microspheres contour to the conformation of the proteins for better coupling efficiency and improved visibility of the agglutinates
- We also make it to your exact specs
Diameter, nm |
Catalog Number |
Carboxyl µEquiv/gram |
Parking Area |
213 |
LP0213CA |
90 |
49.5 |
242 |
LP0242CA |
90 |
43.6 |
308 |
LP0308CA |
115 |
26.8 |
Low-Density Carboxyl Microspheres
Our innovative process technology and formulations have led to the development of novel low-density carboxyl microspheres.
- Optimized levels of carboxyl and sulfate groups for maximum coupling efficiency
- Highly uniform, stable, and reproducible
- Designed to reduce settling
Diameter, nm |
Catalog Number |
Density |
Carboxyl µEquiv/gram |
Parking Area |
106 |
LD0106C3 |
1.03 |
170 |
52.6 |
129 |
LD0129C2 |
1.02 |
202 |
36.4 |
153 |
LD0153C2 |
1.02 |
150 |
41.3 |
298 |
LD0298C3 |
1.03 |
80 |
39.8 |
302 |
LD0302C2 |
1.02 |
80 |
39.3 |
306 |
LD0306C2 |
1.02 |
90 |
34.4 |
310 |
LD0310C1 |
1.01 |
82 |
37.3 |
388 |
LD0388C2 |
1.02 |
120 |
20.4 |
407 |
LD0407C2 |
1.02 |
110 |
21.2 |
421 |
LD0421C2 |
1.02 |
75 |
30.0 |
489 |
LD0489C2 |
1.02 |
124 |
15.6 |
1117 |
LD1117C4 |
1.035 |
59 |
14.4 |
1730 |
LD1730C4 |
1.035 |
26 |
21.1 |
Non-polystyrene Carboxyl microspheres
These microspheres are designed to reduce non-specific binding and are easy to centrifuge.
Diameter, nm |
Catalog Number |
Carboxyl µEquiv/gram |
Parking Area |
98 |
NP0098D |
105 |
92.2 |
168 |
NP0168C |
164 |
34.4 |
194 |
NP0194C |
148 |
33.0 |
298 |
NP0298C |
72 |
44.2 |
402 |
NP0402B |
62 |
38.1 |
High-Density Carboxyl Microspheres
Diameter, nm |
Catalog Number |
Density |
Carboxyl µEquiv/gram |
Parking Area |
100 |
HD0100C2 |
1.19 |
102 |
93.0 |
170 |
HD0170C2 |
1.19 |
160 |
34.9 |
200 |
HD0200C2 |
1.19 |
150 |
31.6 |
300 |
HD0300C2 |
1.19 |
70 |
45.2 |
400 |
HD0400C3 |
1.19 |
60 |
39.5 |
Soap-Free Carboxyl Microspheres
Our distinctive soap-free carboxyl microspheres have the following unique features:
- Optimum sulfate and carboxyl groups to stabilize the microparticles
- Innovative process technology and formulation provide stability and uniformity throughout the polymerization
- Optimized levels of carboxyl groups and uniform surface morphology for maximum coupling efficiency. No excess sulfate groups to interfere with coupling chemistry.
- Very uniform, stable, and reproducible
- Fluorescent and Dyed microspheres: Available in selected sizes
- We also make it to your exact specs
Diameter, nm |
Catolog Number |
Carboxyl µEquiv/gram |
Parking Area |
100 |
SF0100C |
170 |
55.8 |
120 |
SF0120C |
190 |
41.6 |
135 |
SF0135C |
200 |
35.1 |
146 |
SF0146C |
105 |
61.9 |
172 |
SF0172C |
160 |
34.5 |
195 |
SF0195C |
200 |
24.3 |
202 |
SF0202C |
165 |
28.5 |
300 |
SF0300C |
110 |
28.7 |
380 |
SF0380C |
80 |
31.2 |
600 |
SF0600C |
110 |
14.4 |
Fluorescent / Dyed Carboxyl Microspheres
Standard Colors: Fluorescent Yellow, Blue, Red, Hot Pink, Pink, Violet, Coral, Lavender, and other colors
We can dye any product in this catalog to the color of your choice.
Ready-to-Couple Products
Ready-to-Couple™ Chloromethyl Microspheres
PolyMicrospheres proprietary formulations and innovative process technology have led to the development of highly stable and very uniform chloromethyl microspheres. These ready-to-couple microspheres are perfect diagnostic particles with activated groups already attached to the microspheres.
- Preactivated and ready for covalent coupling
- Just adjust the pH and stir at room temp
- High stability and long shelf life
- Simple one-step coupling chemistry
- Optimized levels of chloromethyl groups and uniform surface morphology for maximum coupling efficiency
- Highly uniform, stable, and reproducible
- We also make it to your exact specs
Note: Chloromethyl is the best choice for simple one-step covalent coupling to microspheres
Diameter, nm |
Catalog Number |
95 |
CL0095A |
195 |
CL0195B |
246 |
CL0246B |
280 |
CL0280B |
304 |
CL0304B |
360 |
CL0360B |
405 |
CL0405B |
Ready-to-Couple™ Epoxy Microspheres
PolyMicrospheres proprietary formulations and innovative process technology have led to the development of preactivated and very stable epoxy microspheres for easy covalent coupling. The epoxy microspheres are ready-to-couple diagnostic particles with activated groups already attached to the microspheres.
- Preactivated and ready for covalent coupling
- Fast and easy one-step coupling
- Optimized levels of epoxy groups and uniform surface morphology for maximum coupling efficiency
- Highly uniform, stable, and reproducible
- We also make it to your exact specs
Diameter, nm |
Catalog Number |
Type |
105 |
EP0105B |
Epoxy-II |
228 |
EP0228B |
Epoxy-II |
314 |
EP0314B |
Epoxy-II |
383 |
EP0383B |
Epoxy-II |
585 |
EP0585B |
Epoxy-II |
Plain-surface Products
Polystyrene Microspheres
The polystyrene microspheres are specifically designed for diagnostic assays and optimized for superior performance. Our proprietary formulations and process techniques have resulted in uniform, stable, and reproducible microspheres.
- Optimized levels of sulfate groups to stabilize the microparticles
- Very uniform surface morphology for best passive adsorption
- Can be used without precleaning for most applications
- Fluorescent and Dyed microspheres: Available in selected sizes
Diameter, nm |
Catalog Number |
45 |
PS0045P |
50 |
PS0050P |
65 |
PS0065P |
85 |
PS0085P |
95 |
PS0095P |
100 |
PS0100P |
115 |
PS0115P |
125 |
PS0125P |
160 |
PS0160P |
195 |
PS0195P |
200 |
PS0200P |
225 |
PS0225P |
250 |
PS0250P |
300 |
PS0300P |
320 |
PS0320P |
355 |
PS0355P |
370 |
PS0370P |
390 |
PS0390P |
400 |
PS0400P |
530 |
PS0530P |
570 |
PS0570P |
600 |
PS0600P |
1000 |
PS1000P |
1300 |
PS1300P |
1600 |
PS1600P |
1700 |
PS1700P |
1800 |
PS1800P |
Lightly Hydrophilic Polystyrene Microspheres
These microspheres are designed to enhance stability, passive adsorption, and reactivity.
Diameter, nm |
Catalog Number |
195 |
PS0195H |
300 |
PS0300H |
358 |
PS0358H |
408 |
PS0408H |
614 |
PS0614H |
840 |
PS0840H |
934 |
PS0934H |
1020 |
PS1020H |
Omni-Bind™ Lipophilic Plain-Surface Microspheres
Our innovative process technology and formulations have led to the development of novel lipophilic (lipid incorporated/coated) microspheres for better binding of proteins. Microspheres have been developed to increase the binding efficiency of various proteins.
- The lipid incorporated/coated microspheres contour to the conformation of the proteins for better adsorption/binding efficiency and improved visibility of the agglutinates
- We also make it to your exact specs
Diameter, nm |
Catalog Number |
109 |
LP0109A |
119 |
LP0119A |
160 |
LP0160E |
173 |
LP0173E |
313 |
LP0313E |
394 |
LP0394E |
535 |
LP0535C |
Low-Density Plain-Surface Microspheres
These microspheres are highly uniform, stable, and reproducible. They are designed to reduce settling.
Diameter, nm |
Catalog Number |
Density |
105 |
LD0105P3 |
1.025 |
179 |
LD0179P3 |
1.025 |
249 |
LD0249P3 |
1.025 |
306 |
LD0306P3 |
1.025 |
414 |
LD0414P2 |
1.02 |
415 |
LD0415P1 |
1.01 |
418 |
LD0418P3 |
1.025 |
559 |
LD0559P3 |
1.025 |
723 |
LD0723P1 |
1.01 |
1060 |
LD1060P1 |
1.01 |
1460 |
LD1460P2 |
1.02 |
Non-polystyrene Plain-surface Microspheres
These microspheres are designed to reduce non-specific binding and are easy to centrifuge.
Diameter, nm |
Catalog Number |
100 |
NP0100P |
198 |
NP0198P |
300 |
NP0300P |
400 |
NP0400P |
High-Density Microspheres
Diameter, nm |
Catalog Number |
Density |
88 |
HD0088P4 |
1.37 |
95 |
HD0095C1 |
1.09 |
184 |
HD0184P5 |
1.53 |
195 |
HD0195C1 |
1.09 |
198 |
HD0198P2 |
1.19 |
246 |
HD0246C1 |
1.09 |
300 |
HD0300P2 |
1.19 |
304 |
HD0304C1 |
1.09 |
360 |
HD0360C1 |
1.09 |
400 |
HD0400P2 |
1.19 |
405 |
HD0405C1 |
1.09 |
Soap-Free Polystyrene Microspheres
Our pioneering research in microparticle technology has led to the development of distinctive soap-free microspheres with the following unique features:
- Optimum sulfate groups to stabilize the microparticles
- Innovative process technology and formulation provide stability and uniformity throughout the polymerization
- No excess sulfate groups to interfere with passive adsorption
- Very uniform, stable, and reproducible
- Fluorescent and Dyed microspheres: Available in selected sizes
- We also make it to your exact specs
Diameter, nm |
Catalog Number |
100 |
SF0100P |
200 |
SF0200P |
300 |
SF0300P |
355 |
SF0355P |
400 |
SF0400P |
600 |
SF0600P |
1000 |
SF1000P |
Fluorescent / Dyed Polystyrene Microspheres
Standard Colors: Fluorescent Yellow, Blue, Red, Hot Pink, Pink, Violet, Coral, Lavender, and other colors
We can dye any product in this catalog to the color of your choice.
Other Products
SupraMag™ Superparamagnetic Microparticles
PolyMicrospheres innovation in immunomagnetic research has led to the development of novel superparamagnetic microparticles with the highest magnetic loading and optimized levels of functional groups for covalent coupling of ligands. These highly attractive superparamagnetic microparticles also provide high surface area. The following products exhibit higher attraction to the magnet than typical 1-4 µM magnetic particles.
- Highest magnetic attraction
Diameter, µM |
Functionality |
Catalog No. |
0.2 |
Amino |
SM0200N |
0.25 |
Amino |
SM0250N |
0.25 |
Chloromethyl |
SM0250CL |
0.3 |
Amino |
SM0300N |
0.3 |
Chloromethyl |
SM0300CL |
0.3 |
Sulfhydryl |
SM0300SH |
0.4 |
Amino |
SM0400N |
0.4 |
Chloromethyl |
SM0400CL |
0.5 |
Amino |
SM0500N |
0.5 |
Chloromethyl |
SM0500CL |
0.6 |
Amino |
SM0600N |
0.6 |
Chloromethyl |
SM0600CL |
0.7 |
Amino |
SM0700N |
0.8 |
Amino |
SM0800N |
1.0 |
Amino |
SM1000N |
Large Microbeads
Product |
Diameter Range, µM |
Mean Diameter, µM |
Polystyrene microbeads
density = 1.05 |
|
~ 9 |
75-125 |
|
125-210 |
|
125-300 |
|
210-300 |
|
|
<= 300 |
300-425 |
|
PS-Carboxyl microbeads
density = 1.05 |
75-125 |
|
75-125 |
~ 110 |
125-210 |
|
125-210 |
~ 150 |
125-210 |
~ 158 |
150-250 |
~ 200 |
140-300 |
~ 235 |
140-300 |
~ 240 |
210-300 |
~ 240 |
210-300 |
~ 260 |
PS-Carboxyl microbeads
density = 1.04 |
37-300 |
|
PS-SpaceLink Carboxyl microbeads
density = 1.05 |
75-125 |
~ 105 |
125-210 |
~ 155 |
210-300 |
~ 220 |
300-425 |
~ 260 |
PS-Hydroxyl microbeads
density = 1.04 |
75-125 |
|
125-210 |
|
PS-Gelatin coated microbeads
density = 1.05 |
75-125 |
|
125-300 |
|
300-425 |
|
425-700 |
|
PS-Low Density microbeads
density = 1.03 |
75-125 |
|
|
~ 123 |
|
~ 152 |
|
~ 166 |
210-250 |
|
250-300 |
|
37-300 |
|
PS-Low Density microbeads
density = 1.04 |
37-300 |
|
Chloromethyl microbeads
--CH2Cl |
37-75 |
|
75-125 |
|
125-212 |
|
212-250 |
|
250-300 |
|
300-425 |
|
385-535 |
~ 465 |
订购信息:
北京来福赛思科技有限公司
Tel: 010-57017625/57018690
FAX: 010-81743370
Mail:info@bj-life-science.com
更多产品信息请参看官网:http://www.polymicrospheres.com/ |